ORING IES-180B
Industrial 8-port mini type unmanaged Ethernet switch with 8×10/100Base-T(X)
IES-180B is unmanaged Ethernet switch with 8×10/100Base-T(X) ports. With very compact size of housing, you can install IES-180B easily. In addition, IES-180B is with rigid IP-30 housing design and can operate under harsh environment.
KEY FEATURES:
- Supports 8 ports 10/100 Base-T(X)
- Supports auto-negotiation and auto-MDI/MDI-X
- Supports store and forward transmission
- Supports flow control
- Compact size for easily installation
- Rigid IP-30 housing design

10/100Base-T(X) Ports in RJ45 Auto MDI/MDIX | 8 |
---|---|
Gigabit Combo Ports with 10/100/1000Base-T(X) and 1000Base-X SFP Port | – |
Fiber Ports Number | – |
Fiber Ports Standard | – |
Fiber Mode | – |
Fiber Diameter (μm) | – |
Fiber Optical Connector | – |
Typical Distance (km) | – |
Wavelength (nm) | – |
Max. Output Optical Power (dBm) | – |
Min. Output Optical Power (dBm) | – |
Max. Input Optical Power (Saturation) | – |
Min. Input Optical Power | – |
Link Budget (dB) | – |
Ethernet Standards | IEEE 802.3 for 10Base-T |
MAC Table | 1K MAC addresses |
Priority Queues | – |
Switch Properties | – |
Power Indicator | Green : Power LED x 2 |
Fault Indicator | Amber : Indicates power failure occurred |
10/100Base-FX RJ45 Port Indicator | Upper for Link/Act indicator, Green for port Link/Act. Lower for speed indicator, Amber for 100Mbps, OFF for 10Mbps |
100Base-FX Fiber Port Indicator | – |
Relay | Relay output to carry capacity of 1A at 24VDC |
Redundant Input Power | Dual 12~48 VDC power input on 4-pin terminal block |
Power Consumption (Typ.) | 4 Watts |
Enclosure | IP-30 |
Dimensions (W x D x H) | 41 (W) x 90 (D) x 95 (H)mm (1.61 x 3.54 x 3.74 inch) |
Weight (g) | 383 g |
Storage Temperature | -40 to 85°C (-40 to 185°F) |
Operating Temperature | -40 to 75°C (-40 to 167°F) |
Operating Humidity | 5% to 95% Non-condensing |
EMC | – |
EMI | FCC Part 15, CISPR (EN55022) class A |
EMS | IEC61000-4-2 (ESD), IEC61000-4-3 (RS), IEC61000-4-4 (EFT), IEC61000-4-5 (Surge), IEC61000-4-6 (CS), IEC61000-4-8, IEC61000-4-11 |
Shock | IEC60068-2-27 |
Free Fall | IEC60068-2-32 |
Vibration | IEC60068-2-6 |
Safety | EN60950-1 |
MTBF | – |