ORING IES-1160
Industrial 16-port unmanaged Ethernet switch with 16×10/100Base-T(X)
IES-1160 is the unmanaged Ethernet switch with 16×10/100Base-T(X) port. IES-1160 support redundant power inputs, relay output alarm, and surge protection. The wide operating temperature range from -40°C to 70°C can satisfy most of operating environments.
KEY FEATURES:
- RJ-45 ports support Auto MDI/MDI-X switching function
- Provides Store-and-Forward switching architecture
- Provides 3.2Gbps Back-plane (Switching Fabric)
- Warning system by relay output
- Rigid IP-30 housing design
- DIN-Rail and wall mounting enabled
10/100Base-T(X) Ports in RJ45 Auto MDI/MDIX | 16 |
---|---|
1000Base-X SFP ports | – |
Fiber Ports Number | – |
Fiber Ports Standard | – |
Fiber Mode | – |
Fiber Diameter (μm) | – |
Fiber Optical Connector | – |
Typical Distance (km) | – |
Wavelength (nm) | – |
Max. Output Optical Power (dBm) | – |
Min. Output Optical Power (dBm) | – |
Max. Input Optical Power (Saturation) | – |
Min. Input Optical Power | – |
Link Budget (dB) | – |
Ethernet Standards | IEEE 802.3 for 10Base-T |
MAC Table | 8192 MAC addresses |
Priority Queues | 4 |
Switch Properties | Switching latency: 9 μs |
Power Indicator | Green : Power LED x 3 |
Fault Indicator | Amber : Indicates power failure occurred |
10/100Base-FX RJ45 Port Indicator | Green for port Link/Act. Amber for Duplex/Collision |
100Base-FX SFP Port Indicator | – |
Relay | Relay output to carry capacity of 1A at 24VDC |
Redundant Input Power | Dual DC inputs. 12 ~ 48VDC on 6-pin terminal block |
Power Consumption (Typ.) | 9 Watts |
Enclosure | IP-30 |
Dimensions (W x D x H) | 74.3(W)x109.2(D)x153.6(H) mm (2.93 x 4.3 x 6.05 inch) |
Weight (g) | 1060 g |
Storage Temperature | -40 to 85°C (-40 to 185°F) |
Operating Temperature | -40 to 70°C (-40 to 158°F) |
Operating Humidity | 5% to 95% Non-condensing |
EMC | – |
EMI | FCC Part 15, CISPR (EN55022) class A |
EMS | IEC61000-4-2 (ESD), IEC61000-4-3 (RS), IEC61000-4-4 (EFT), IEC61000-4-5 (Surge), IEC61000-4-6 (CS), IEC61000-4-8, IEC61000-4-11 |
Shock | IEC60068-2-27 |
Free Fall | IEC60068-2-32 |
Vibration | IEC60068-2-6 |
Safety | EN60950-1 |
MTBF | 267,635 |